16:28
How To Wire a 3-Way Switch System
Sparky Channel
30:32
IDEAL National Championship Semis 2019 Electrical Troubleshooting
1:07:47
IDEAL National Championship 2019 Pro Finals: Service Entrance Cable, Torque, Panels and Breakers
14:27
NEC 2020 404.2(C) Neutrals in Switch Boxes with Example and New 2020 Exceptions
11:17
Is this Box Overfilled by 2020 NEC Code?
8:59
2020 NEC Article 110.14(D) (With Examples) Torque Specifications
4:44
DeWalt Cable Stapler with 2020 NEC 334.30 Securing and Supporting NM Cable
13:58
Test and Replace a Switch + Grades of Switches with 2020 NEC 404.9 Ungrounded Switches
8:45
Leviton Decora Smart New Switches and Receptacles from National Electrical Contractor Association
14:47
Double Switch Test and Replacement for Bath Fan and Light in a 1960 House
15:57
Separate Switches for Bath Fan and Light from Single Switch in a 1960's House
45:29
IDEAL National Championship Finals 2018
14:01
Wago Lever-Nuts Questions and Answers From National Electrical Contractor Convention
5:49
How To Fix an "Open Hot" Receptacle
13:05
How to Fix an Open Ground
4:53
How 1960's Metal Electrical Boxes Were Grounded
5:15
How to Turn Off Ghost Voltages with Dual Impedance (LoZ) Meters
13:37
How to Replace 2 Switches: 3-Way and Single Pole When You Have No Ground per NEC 2020
4:32
Hilti Fastening System for Fastening Ground Cable to Steel from NECA 2019
9:15
Replacing a Vintage 1960 Switch and Grounding the New Switch
4:08
Wet Rated Electrical Gang Box Installation + Installing EMT into an Existing Gang Box
4:11
Back Stab vs. Back Wire (Spec Grade) Receptacles and Switches
12:31
How To Wire 2 Duplex Receptacles + Testing Wires Before and After Installation
7:00
How to Solder Wires Together, Use Heat Shrink Butt Connectors and Use Heat Shrink Protection
14:46
How To Fix a 3-Way Switch System
9:12
How to Wire a Half Hot Receptacle with Power to the Receptacle
14:10
Half Hot Receptacle with Power to Switch Installation
17:10
How to Add a Receptacle to a Lighting Circuit
8:25
Shall I Use a 15A or a 20A Receptacle on a 20A Circuit? + 2020 NEC 210.21(B)(1) and 210.21(B)(3)
29:28
IDEAL National Championship Apprentice 1st Round: 3-Way Switches and Multi-Wire Branch Circuit
20:58
How to Wire a 4-Way Switch System
16:27
How To Fix a 4-Way Switch System
21:09
Leviton Voice Activated Dimmer Switch with Alexa + 2 Switch Remotes (Multi-Location Switching) DWVAA
8:21
Six Types of GFCI and AFCI/GFCI Outlets for Your Home with NEC 2020 Codes
13:27
How to Wire Multiple Lights and How To Prepare Wiring for Drywall
14:50
How To Install A Weather Resistant 20A GFCI and a 20A Receptacle in an Exterior Box
13:32
How to Fix 3-Way Switch Systems with Diagrams Included
16:36
How to Wire a 3-way Switch with Power to Light and 2020 NEC 404.2 (C)
17:22
3 Way Switch with Power to Light: Old Style Wiring, Simple and Effective
19:26
Add a Single Pole Switch to 3-Way Switch System
14:23
How to Install a Double Switch for a Bath Light and Fan
11:47
How To Install an Old Work Box and an Exterior GFCI 20A Receptacle (Weather Resistant)
7:04
Milwaukee Angler Sparky vs Fish Tape Sparky Wire Pulling Contest!
15:42
How to Replace and Ground a Broken Switch in a 1957 House + House Renovation Time Again!
11:31
How to Replace and Ground a Double Switch in a 1957 House
19:47
How to Fix a 3-Way Switch System on a 1957 House: House Renovation Time!
9:03
How to Install a Single-Pole Switch Next to a 3 Way Switch with Discussion of Faded Wires, Grounding
6:02
Which Wire is the Hot and Which is the Neutral in an Old House? How to Tell and Stay Safe!
How to Install the Cheapest Flush Mount Ceiling Light at Home Depot Safely
6:04
How to Install a 20A Spec Grade Microwave Receptacle and an Old Work Box
3:13
3 Ways to Test for Voltage Without Subjecting Yourself to Bare Wires
6:01
Why Isn't My GFCI Receptacle Working? How Long Do They Last?
7:54
How to Wire a 20A GFCI and 20A Receptacle in a 2-Gang Box Fast and Safely
13:08
How to Replace a GFCI Receptacle and Discover What it Protects Downstream
1:54
Why do GFCI Receptacles Say "Charge" on the Back of Them?
9:24
How to Wire a Garbage Disposal (Including Polarity Check for the Wires)
12:27
How to Install a Combination Switch/Receptacle and a Light in Place of a Receptacle
3:33
How to Hook Up the Electrical Cord on a Dishwasher
9:04
How to Wire a Half Hot Receptacle in a 1957 House
13:48
How To Replace 3-Way Switches on a 50's-60's House and Avoid Common Mistakes
4:06
Did I Get Ripped Off Again? Dishwasher Cord Comparison
6:12
Two White Wires in a Light Box, Which One is Hot?
8:17
How to Install a Marked Controlled Receptacle
7:28
Diagram for Marked "Controlled" Receptacles with Discussion
8:40
Ohm's Law and Power Calculations with Examples and Discussion
2:34
What's Wrong? 2021 IDEAL National Championship NEC Violation Board 1st Round Part2 from Nashville!
5:38
Too Many Wires? Part of IDEAL National Championship Round 1 + 2020 NEC Chapter 9, Table 4
EMT Conduit Nipple Fill and Strap Questions NEC Chapter 9 Table 1
20:01
IDEAL National Championship First Round Pros from Nashville
3:47
Do You See Any NEC Code Violations? Pros Round 1 IDEAL National Championship 2021
6:11
How Far Should Sheathing Extend into a Panel? NEC 2020 314.17 (B), 312.5 (C) and 110.12
2:17
What's Wrong? Concentric Knockouts and Conduit Fill, 2020 NEC 250.92 (B), 250.122
2:28
Which is Correct?
27:33
Pro Round 2 IDEAL National Championship from Nashville 2021 Troubleshooting and Panel Installation
27:26
Student Apprentice 2nd Round IDEAL National Championship 2021 from Nashville
4:41
Hey Sparky, Why? Article 250, 2020 NEC
8:05
What's the Difference Between an EGC and a GEC?
17:42
Student Apprentice Semi-finals IDEAL National Championship 2021 from Nashville
32:46
IDEAL National Championship Pro Semi-finals 2021 from Nashville
Do Load Center Terminals Need to be Torqued and Where to Find the Specs? 2020 NEC 110.14 (D)
4:29
What is a Service Conductor? What is a Feeder?
Upside Down Load Center? What Do You Think?
22:15
1st Round Teams Competition IDEAL National Championship 2021 from Nashville
Watch a Pro Wire a 20A GFCI and 20A Receptacle, Any Code Violations?
5:08
Caulking as an NEC Code? Really?
32:23
IDEAL National Championship Pro Finals 2021 $60K for 1st Place, $25K for 2nd and $10K for 3rd!
16:29
IDEAL National Championship Teams Finals 2021 from Nashville $40K to the Winner!
4:15
Stickers Necessary for GFCI Protected Grounded Receptacle?
5:51
In Which Panel are the Neutral and Ground Bonded?
4:00
How to Know What to Torque a Breaker Terminal to?
4:33
What's This Little Door For? And is There a New NEC Code "Behind" it? (2020 NEC 230.82)
7:27
Bonding Screws vs Bonding Straps (NEC 250.24 (B) Main Bonding Jumper
5:05
What is an Invertible Load Center?
6:55
What is a Convertible Load Center and How is it Converted?
6:28
Can EMT Conduit be Used as Equipment Grounding Conductor? NEC 2020 250.118 and 250.119
6:07
Are Fish Tapes Really Necessary All the Time?
6:59
Which is Correct by Code and Most Professional? 2020 NEC 250.64 (E)
5:37
Q-Bit Outlet Box Saw Demonstration and Wiring with 2020 NEC 314.17(B)(2) for Old Work Box Install
7:58
Fast Holes in Drywall with QBits, 4 Sizes! Installations and Reviews
4:43
How and Where to Install Ground Bars on Panels
5:07
What is a CAFI Circuit Breaker and How are They Installed on a Plug-On Neutral Load Center?
3:17
What Do All These Letters and Numbers Mean?
4:56
How to Torque Terminals in a Square D Homeline Load Center
7:30
Siemens vs Homeline: Neutral Bonding Screws + When are They Used?
5:01
How to Trace an Open Circuit Caused by Broken Wires
2:59
Can I Trace a Break in the Neutral When the Hot and Ground are Good?
6:14
Can I find an Electrical Line Under Concrete with the Klein ET450 Circuit Tracer?
4:07
Can an Ideal SureTrace Circuit Tracer Find an Open Neutral and How Does It Compare to A Klein ET450?
9:08
How to Wire GFCI Exterior Receptacles with Weatherproof Cover, Real Time, No Edits
6:34
How to Add a GFCI Protected Receptacle
5:11
Why Doesn't My GFCI Test Button Work?
11:23
Sparky vs the Pros: Wiring
8:24
Milwaukee vs DeWalt Cable Stapler All-Out Contest! in 4K
8:14
Ideal Armourband vs. Electrical Tape, Which Will Win?
A Superior Old Work Electrical Box?
3:55
Installation Problems with an Arlington 2 Screw Device Box?
12:38
Switch Test and Replace, NEC 2020 404.9, "Snap Switch" Definition, and Screwless Wallplate Needed?
How to Extend Short Wires per 2023 NEC 300.14
4:12
Do Solid and Stranded Wires Have Different Conduit Fill Spec? Does the Length of the Conduit Matter?
5:47
Can You Find the NEC Code Violation?
12:03
How to Wire a 3-way Switch Lighting Circuit in EMT Conduit
8:09
Watch a Pro Run 2 Circuits in 1 EMT Conduit and See How a Subpanel Is Wired
Adjustable Electrical Boxes: When and How to Use Them
6:33
How to Install a Receptacle with USB and Type C Charging in a New Backsplash
5:39
Receptacle Strap or Yoke
4:16
How to Install and Troubleshoot End of the Run Receptacles
10:03
Shall I Use 15A or 20A Receptacles on a 20A circuit per 2023 NEC 210.21(B) ?
6:40
Self-Grounding Clips for Receptacles and Switches with 2023 NEC 250.146
1:42:41
Do This Everyday To REDUCE INFLAMMATION & Improve Gut Health | Dr. Deanna Minich
Dhru Purohit
7:08
How to Bond Neutral and Ground With 2023 NEC Code Book and Handbook
4:42
Feed-Through Conductors 2023 NEC 312.8 (A) and (B)
Troubleshooting Ethernet Cable with Modular RJ45 Plugs + How to Find Damaged Area of Cable
9:56
What is This Tab and When Do We Break it?
17:13
Marked Controlled Receptacle: Wiring, 2023 NEC code 406.3(F) and Diagram
8:11
When Must I Use a Marked Controlled Receptacle?
In Which Panel are the Ground and Neutral to be Bonded?
Where to Put Grounding Bushings? 2023 NEC 252.92(B)
5:58
How Much Copper Should Show Between a Lug and Cable Insulation?
10:22
How to Replace a Motor on a Blower Type Bath Fan (Nutone LS80SE)
18:01
How to Put Bath Fan and Light on Separate Switches Instead of on One Switch
7:39
Height of Panels and Working Space Around Panels 2023 NEC 404.8(A) and 110.26
6:56
Combination AFCI Breaker vs Dual Function Breaker: The Differences and Where to Use Them
2:09
Does a Fire Alarm Circuit Need GFCI/AFCI Protection?
12:19
What is a Solar Ready CSED? + How to Calculate Max Solar Capacity