Today's video is a tough one. I found a terminal fault on an old boiler, but the customer thought I was just looking for a big payday. It's the side of the trade that really grinds you down.
Watch how I handled the situation here: ๐๐ฝ
POLL: Whatโs the hardest part of delivering 'bad news' to a customer? ๐ Their lack of trust ๐ค ๐ The cost of the replacement ๐ธ ๐ Explaining 'Obsolete' parts ๐ ๐ Leaving them with no heating ๐ฅถ
Cast your vote and letโs discuss those awkward kitchen-table chats! ๐๐ฝ
ROUND 2: ENGINEER VS. THE WORCESTER! ๐ต๐ฝโโ๏ธโ๏ธ
I thought I had that airlock beaten, but the boiler had other ideas. Iโm back at the job from yesterday to see if I can finally end this nightmare.
Watch the full follow-up and the final fix tonight at 6!
POLL: Whatโs your most common 'false friend' during a diagnosis? ๐ Misdiagnosing air for a dead pump โ๏ธ ๐ Faulty PCB vs. Stuck Valve ๐ ๐ Blocked Heat Exchanger vs. Sludge ๐งฑ ๐ A 'new' part that's actually DOA! ๐ค
Cast your vote and tell me about your worst 'come-back' job in the comments! ๐๐ฝ
Only the second time I've done one of these, and it wasn't as bad as I thought it was going to be ๐๐พ
The way I do it: 1) Remove plate 2) Remove diverter valve 3) Remove flow turbine 4) Undo hot connection 5) Undo screws on flow manifold (LEAVE THE MANIFOLD CONNECTED) 6) Undo the screws holding the bracket to the chassis 7) Manoeuvre the bracket out 8) Replace in reverse order
With any sort of job like this, the most important thing is to take your time and don't rush!
ENGINEER VS. AIRLOCK: The Ultimate Battle! ๐ต๐ฝโโ๏ธโ๏ธ
I spent today being haunted by an open vented system that refused to circulate. Blocked feed? Air-bound exchanger? Weak pump? Iโm breaking down the full diagnostic nightmare in today's video.
Watch the struggle (and the solution) here: ๐๐ฝ
POLL: Whatโs your first move for a stubborn airlock? ๐ Mains pressure back-fill ๐ฐ ๐ Sucking it through with a wet-vac ๐งน ๐ Cutting the H-section out โ๏ธ ๐ Praying to the plumbing gods! ๐๐ฝ
Cast your vote and tell me your best airlock-busting tips! ๐๐ฝ
Ripping out old thermal stores is back-breaking work, but the trip to the scrap yard makes it all worth it. I'm showing you the weigh-in from my latest clear-out in today's video.
Live tonight at 6!
POLL: How do you handle your scrap? ๐ Weigh it in monthly for a 'bonus' ๐ธ ๐ Save it all year for Christmas ๐ ๐ฝ ๐ Give it to the apprentice/scrap man ๐ ๐ It just piles up in the garage... ๐ฆ
Cast your vote and let me know your best scrap-run tips! ๐๐ฝ
Today's video is a madness. A Viessmann boiler, 6 visits from their own team, and still no hot water or heating.
POLL: Who do you trust more for a complex fault? ๐ Independent Pro (The 'Real World' guys) ๐ ๏ธ ๐ Manufacturer Engineer (The 'Factory' guys) ๐ญ ๐ A specialist diagnostic firm ๐ง ๐ Iโll just fix it myself! ๐
Cast your vote and tell me why the 'factory' guys sometimes miss the obvious! ๐๐ฝ
Is your powerflushing as efficient as it could be?
Tonight's video is a deep dive into using a Pump Head Adapter for powerflushing. Itโs a game-changer for keeping the job tidy and getting the best possible flow through the system.
Check out the full setup and my top tips here: ๐๐ฝ
POLL: Whatโs your biggest frustration when powerflushing? ๐ Leaking connections ๐ง ๐ Not getting enough flow ๐ ๐ How long the process takes โณ ๐ Messy cleanup after the job ๐งน
Cast your vote and letโs talk shop in the comments! ๐๐ฝ
I was called out for a simple E133 fault today, but what I found inside the heat exchanger was a total disaster. Despite being serviced recently, the main heat exchanger has failed and the damage is terminal.
The full diagnosis is live now! Watch it and tell me how youโd handle this one: ๐๐ฝ
POLL: Whatโs the hardest part of being a heating engineer? ๐ Breaking news of a terminal fault ๐ ๐ Finding a mistake from a previous service ๐คฆ๐ฝโโ๏ธ ๐ Intermittent faults that won't show up ๐ต๐ฝโโ๏ธ ๐ The 'I could've done it cheaper' crowd ๐
Cast your vote and let me know your toughest customer conversations below! ๐๐ฝ
Iโve seen some bad installs in my time, but this one takes the cake. Since 2012, these homeowners haven't had reliable hot water. After a decade of failed repairs, it turns out the whole system was fundamentally flawed from day one.
Iโve just finished ripping it out and replacing it with a fresh Baxi & Joule Cyclone setup to finally give them the hot water theyโve been waiting a decade for.
The full reveal and the 'Aha!' moment are live tonight at 6! ๐๐ฝ
POLL: Whatโs the longest youโve ever seen a fault go ignored? ๐ 1-2 Years โ Long enough! ๐๏ธ ๐ 5 Years โ A proper nightmare ๐ค ๐ 10+ Years โ Impossible, but true! ๐คฏ ๐ Iโve found stuff from the 90s... ๐ด๐ฝ
Cast your vote and tell me the maddest thing you've ever found in a cylinder cupboard in the comments! ๐๐ฝ
Are we being sold overpriced 'Branded' parts? ๐ง๐ธ
In today's video, Iโm showing how I save customers nearly ยฃ100 just by picking the right pump. Itโs the exact same tech, just without the fancy box.
I want to know what you think is the biggest 'Brand Tax' in the trade right now.
Which of these do you think is the most expensive for a branded label? ๐๐ฝ
CP Utility Solutions
ENGINEER VS. SKEPTICISM! ๐ต๐ฝโโ๏ธโ๏ธ
Today's video is a tough one. I found a terminal fault on an old boiler, but the customer thought I was just looking for a big payday. It's the side of the trade that really grinds you down.
Watch how I handled the situation here: ๐๐ฝ
POLL: Whatโs the hardest part of delivering 'bad news' to a customer?
๐ Their lack of trust ๐ค
๐ The cost of the replacement ๐ธ
๐ Explaining 'Obsolete' parts ๐
๐ Leaving them with no heating ๐ฅถ
Cast your vote and letโs discuss those awkward kitchen-table chats! ๐๐ฝ
2 days ago | [YT] | 12
View 10 replies
CP Utility Solutions
ROUND 2: ENGINEER VS. THE WORCESTER! ๐ต๐ฝโโ๏ธโ๏ธ
I thought I had that airlock beaten, but the boiler had other ideas. Iโm back at the job from yesterday to see if I can finally end this nightmare.
Watch the full follow-up and the final fix tonight at 6!
POLL: Whatโs your most common 'false friend' during a diagnosis?
๐ Misdiagnosing air for a dead pump โ๏ธ
๐ Faulty PCB vs. Stuck Valve ๐
๐ Blocked Heat Exchanger vs. Sludge ๐งฑ
๐ A 'new' part that's actually DOA! ๐ค
Cast your vote and tell me about your worst 'come-back' job in the comments! ๐๐ฝ
6 days ago | [YT] | 13
View 2 replies
CP Utility Solutions
Vaillant Support Bracket Replacement 178965
Only the second time I've done one of these, and it wasn't as bad as I thought it was going to be ๐๐พ
The way I do it:
1) Remove plate
2) Remove diverter valve
3) Remove flow turbine
4) Undo hot connection
5) Undo screws on flow manifold (LEAVE THE MANIFOLD CONNECTED)
6) Undo the screws holding the bracket to the chassis
7) Manoeuvre the bracket out
8) Replace in reverse order
With any sort of job like this, the most important thing is to take your time and don't rush!
Have you done one of these before?
What's your preferred method to do these?
Let me know in the comments below ๐๐พ
#vaillant #boiler #boilerrepair #gas #picoftheday
1 week ago | [YT] | 52
View 8 replies
CP Utility Solutions
ENGINEER VS. AIRLOCK: The Ultimate Battle! ๐ต๐ฝโโ๏ธโ๏ธ
I spent today being haunted by an open vented system that refused to circulate. Blocked feed? Air-bound exchanger? Weak pump? Iโm breaking down the full diagnostic nightmare in today's video.
Watch the struggle (and the solution) here: ๐๐ฝ
POLL: Whatโs your first move for a stubborn airlock?
๐ Mains pressure back-fill ๐ฐ
๐ Sucking it through with a wet-vac ๐งน
๐ Cutting the H-section out โ๏ธ
๐ Praying to the plumbing gods! ๐๐ฝ
Cast your vote and tell me your best airlock-busting tips! ๐๐ฝ
1 week ago | [YT] | 22
View 10 replies
CP Utility Solutions
THE SCRAP HUSTLE! ๐ฎ๐ธ
Ripping out old thermal stores is back-breaking work, but the trip to the scrap yard makes it all worth it. I'm showing you the weigh-in from my latest clear-out in today's video.
Live tonight at 6!
POLL: How do you handle your scrap?
๐ Weigh it in monthly for a 'bonus' ๐ธ
๐ Save it all year for Christmas ๐ ๐ฝ
๐ Give it to the apprentice/scrap man ๐
๐ It just piles up in the garage... ๐ฆ
Cast your vote and let me know your best scrap-run tips! ๐๐ฝ
1 week ago | [YT] | 9
View 13 replies
CP Utility Solutions
Today's video is a madness. A Viessmann boiler, 6 visits from their own team, and still no hot water or heating.
POLL: Who do you trust more for a complex fault?
๐ Independent Pro (The 'Real World' guys) ๐ ๏ธ
๐ Manufacturer Engineer (The 'Factory' guys) ๐ญ
๐ A specialist diagnostic firm ๐ง
๐ Iโll just fix it myself! ๐
Cast your vote and tell me why the 'factory' guys sometimes miss the obvious! ๐๐ฝ
2 weeks ago | [YT] | 19
View 2 replies
CP Utility Solutions
Is your powerflushing as efficient as it could be?
Tonight's video is a deep dive into using a Pump Head Adapter for powerflushing. Itโs a game-changer for keeping the job tidy and getting the best possible flow through the system.
Check out the full setup and my top tips here: ๐๐ฝ
POLL: Whatโs your biggest frustration when powerflushing?
๐ Leaking connections ๐ง
๐ Not getting enough flow ๐
๐ How long the process takes โณ
๐ Messy cleanup after the job ๐งน
Cast your vote and letโs talk shop in the comments! ๐๐ฝ
2 weeks ago | [YT] | 10
View 0 replies
CP Utility Solutions
The worst news an engineer can give... ๐๐ธ
I was called out for a simple E133 fault today, but what I found inside the heat exchanger was a total disaster. Despite being serviced recently, the main heat exchanger has failed and the damage is terminal.
The full diagnosis is live now! Watch it and tell me how youโd handle this one: ๐๐ฝ
POLL: Whatโs the hardest part of being a heating engineer?
๐ Breaking news of a terminal fault ๐
๐ Finding a mistake from a previous service ๐คฆ๐ฝโโ๏ธ
๐ Intermittent faults that won't show up ๐ต๐ฝโโ๏ธ
๐ The 'I could've done it cheaper' crowd ๐
Cast your vote and let me know your toughest customer conversations below! ๐๐ฝ
3 weeks ago | [YT] | 17
View 3 replies
CP Utility Solutions
NO HOT WATER FOR 10 YEARS?! ๐คฏ๐ฟ
Iโve seen some bad installs in my time, but this one takes the cake. Since 2012, these homeowners haven't had reliable hot water. After a decade of failed repairs, it turns out the whole system was fundamentally flawed from day one.
Iโve just finished ripping it out and replacing it with a fresh Baxi & Joule Cyclone setup to finally give them the hot water theyโve been waiting a decade for.
The full reveal and the 'Aha!' moment are live tonight at 6! ๐๐ฝ
POLL: Whatโs the longest youโve ever seen a fault go ignored?
๐ 1-2 Years โ Long enough! ๐๏ธ
๐ 5 Years โ A proper nightmare ๐ค
๐ 10+ Years โ Impossible, but true! ๐คฏ
๐ Iโve found stuff from the 90s... ๐ด๐ฝ
Cast your vote and tell me the maddest thing you've ever found in a cylinder cupboard in the comments! ๐๐ฝ
3 weeks ago | [YT] | 24
View 1 reply
CP Utility Solutions
Are we being sold overpriced 'Branded' parts? ๐ง๐ธ
In today's video, Iโm showing how I save customers nearly ยฃ100 just by picking the right pump. Itโs the exact same tech, just without the fancy box.
I want to know what you think is the biggest 'Brand Tax' in the trade right now.
Which of these do you think is the most expensive for a branded label? ๐๐ฝ
POLL:
๐ Branded Pumps (WB, Vaillant, etc.) ๐ง
๐ Magnetic Filters ๐งฒ
๐ Smart Controls/Stats ๐ฑ
๐ Standard Gaskets/Washers ๐ ๏ธ
Cast your vote and tell me your best 'OEM' alternative in the comments! ๐๐ฝ
1 month ago | [YT] | 10
View 9 replies
Load more